cloud_point_hero

CpCloud Point Analyser

Determines the lowest temperature at which a fuel may be used without wax formation

Cloud Point combines icon scientific’s innovative analytical engine into a next-generation analyser designed to deliver maximum performance.

DOWNLOAD BROCHURE
cp_screen_small
Analyzer

Cloud Point

Class-leading repeatability

Cloud Point’s enhanced performance uses sophisticated proprietary technologies more reliable than those used in traditional cloud point analysers

Typically used to measure diesel fuel, Cloud Point’s analysis measurement is achieved through a unique low mass-measuring cell, non-contact light source and proprietary vacuum insulation system detector for outstanding thermal performance – without the need for an external cooler.

Enquire

How Cloud Point works

Advanced thermoelectric cooling and optical detection systems provide exceptional results, in most cases without the need for chilled water

The low mass measuring cell traps a small amount of the sample. This is then cooled at a controlled rate by the Peltier-based thermoelectric cooler using a pulse width modulated control signal. The cooling continues until sufficient light-scatter is detected from precipitating wax crystals to trigger cloud point detection. The old sample is then flushed away and the cycle is repeated. If the sample enters the unit at too low a temperature, the Peltier control is reversed to warm the sample before carrying on with the analysis.

Enquire
cp_screen_large
repeatability_icon

Excellent repeatability

Advanced detection algorithms and pulse width modulated variable-rate Peltier cooler control ensures Cloud Point achieves better repeatability than the standard test methods.

performance_icon

Best in class cooling performance

With reduced thermal losses thanks to the low mass measuring cell, patented vacuum insulation system and non-contacting light source and detector, this provides the highest differential between cooling water temperature and the lowest measurable cloud point.

accuracy_icon

Increased measuring cell life

As well as giving improved cooling performance, icon’s patent vacuum insulation eliminates premature cell failure caused by condensation and cooling errors due to ice formation.

cleaning_icon

Compliant

Results are compatible with those of any standard cloud point test methods including ASTM D2500 and ASTM D5771/2/3

quote_0

To arrange a demo or find out more about the Cloud Point Analyser call +44 (0) 1225 667 050 or complete the form below.

Find out more about how we're changing the face of process analysis.

+44 (0)1225 667 050

info@iconscientific.com

Contact the team

TO KEEP UP TO DATE WITH ALL ICON’S LATEST INTELLIGENCE, PLEASE SIGN UP BELOW.

You can unsubscribe from the Newsletter at any time, this process is laid out in our Privacy Policy

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.